COSMOSOLAR D.H.W. tanks , BLGLL series, are distinguished for the excellent build quality, the high efficiency and longevity.

  • With high quality steel protected against corrosion with epoxy resin protection

, COSMOSOLAR Ltd. ensures the high quality of the tanks, by strictly observing ICO procedures in the production with its highly trained technical staff.

All tanks have a magnesium rode for extra cathodic protection.

The heat exchanger is made of steel, coil type with 10 bars maximum working pressure and 95 oC as maximum working temperature



The COSMOSOLAR D.H.W. tanks minimize the heat loss having a strong isolation of polyurethane which embraces the body of the tank minimizing the heat loss. The out cover is soft PVC

There are three (3) types of D.H.W. tanks :

  • WITH TWO FLADGES (WITHOUT HEAT EXCHANGERS)

  • WITH ONE REMOVABLE HEAT EXCHANER AND ONE FLADGE

  • WITH TWO REMOVABLE HEAT EXCHANERS

Under your request, all BLGLL tanks are delivered with:

  • steel out cover for outside installation
  • Electric heating element
You can find more information about the COSMOSOLAR D.H.W. TANKS, as well as, complete technical data in TECHNICAL.COSMOSOLAR
recycle
carbon
COSMOSOLAR D.H.W. TANKS, like all COSMOSOLAR products, are fully recyclable and environmentally friendly, contributing to the protection of the environment.

MODELS

WITH TWO FLADGES (WITHOUT HEAT EXCHANGERS)

CODE

DESCRIPTION

CAPACITY (L)

BLGLL50/0

500 without heat exchanger and with two flanges

478

BLGLL75/0

750 without heat exchanger and with two flanges

741

BLGLL100/0

1000 without heat exchanger and with two flanges

863

BLGLL150/0

1500 without heat exchanger and with two flanges

1680

BLGLL200/0

2000 without heat exchanger and with two flanges

1980

BLGLL300/0

3000 without heat exchanger and with two flanges

2990

BLGLL400/0

4000 without heat exchanger and with two flanges

3960

BLGLL500/0

5000 without heat exchanger and with two flanges

4920

BLGLL700/0

7000 without heat exchanger and with two flanges

7150

BLGLL900/0

9000 without heat exchanger and with two flanges

9040

 

WITH ONE REMOVABLE HEAT EXCHANGER AND ONE FLADGE

CODE

DESCRIPTION

CAPACITY (L)

BLGLL50D/2,2*

500 with one flange and with removable heat exchanger 2,2m2

463

BLGLL750D/3,2

750 with one flange and with removable heat exchanger 3,2m2

719

BLGLL100D/3,2

1000 with one flange and with removable heat exchanger 3,2m2

842

BLGLL150D/3,2

1500 with one flange and with removable heat exchanger 3,2m2

1659

BLGLL150D/5,4

1500 with one flange and with removable heat exchanger 5,4m2

1645

BLGLL200D/3,2

2000 with one flange and with removable heat exchanger 3,2m2

1959

BLGLL200D/5,4

2000 with one flange and with removable heat exchanger 5,4m2

1945

BLGLL300D/3,2

3000 with one flange and with removable heat exchanger 3,2m2

2954

BLGLL300D/5,4

3000 with one flange and with removable heat exchanger 5,4m2

2932

BLGLL400D/5,4

4000 with one flange and with removable heat exchanger 5,4m2

3960

BLGLL500D/5,4

5000 with one flange and with removable heat exchanger 5,4m2

4890

BLGLL700D/7,8

7000 with one flange and with removable heat exchanger 7,8m2

7065

BLGLL900D/7,8

9000 with one flange and with removable heat exchanger 7,8m2

8958

* Surface in sq.m. of the heat exchanger

WITH TWO REMOVABLE HEAT EXCHANERS

CODE

DESCRIPTION

CAPACITY (L)

BLGLL50T/4,4*

500 with 2 heat exchangers 2,2

448

BLGLL75T/6,4

750 with 2 heat exchangers 3,2

698

BLGLL100T/6,4

1000 with 2 heat exchangers 3,2

821

BLGLL150T/6,4

1500 with 2 heat exchangers 3,2

1638

BLGLL150T/10,8

1500 with 2 heat exchangers 5,4

1610

BLGLL200T/6,4

2000 with 2 heat exchangers 3,2

1938

BLGLL200T/10,8

2000 with 2 heat exchangers 5,4

1910

BLGLL300T/6,4

3000 with 2 heat exchangers 3,2

2918

BLGLL300T/10,8

3000 with 2 heat exchangers 5,4

2875

BLGLL400T/10,8

4000 with 2 heat exchangers 5,4

3960

BLGLL500T/10,8

5000 with 2 heat exchangers 5,4

4800

BLGLL700T/15,6

7000 with 2 heat exchangers 7,8

6995

BLGLL900T/15,6

9000 with 2 heat exchangers 7,8

8880